·Strand, tinned or bare conductor, 40 AWG minimum,material not specified.
·Irradiated Polyethylene insulation.
·OUTERMOST COVERING: Extruded PVC, Irradiated PE, FRPE
·Rated temperature:60℃,80℃.
.Rated voltage: 30volts ac.
·Uniform thickness of wire to ensure easy stripping and cutting.
·VW-1 flame rating not authorized when not employing covering.
·Passes UL approval
·Refer to standard UL 758/UL1581
·Irradiated Polyethylene insulation.
·OUTERMOST COVERING: Extruded PVC, Irradiated PE, FRPE
·Rated temperature:60℃,80℃.
.Rated voltage: 30volts ac.
·Uniform thickness of wire to ensure easy stripping and cutting.
·VW-1 flame rating not authorized when not employing covering.
·Passes UL approval
·Refer to standard UL 758/UL1581
APPLICATIONS
·Internal Wiring of Electronic Equipment in Class 2 Circuits only
CONSTRUCTION:
Size | Conductor construction | Stranding Diameter | Insulation Thickness | Overall Diameter | Covering Thickness | Overall Diameter | Standard put-up | |
AWG | No./mm | mm | mm | mm | (PVC) mm | mm | Feet/coil | Meter/coil |
30 | 7/0.10 | 0.31 | 0.64 | 1.59 | 0.36 | 2.35 | 2000 | 610 |
28 | 7/0.12 | 0.37 | 0.64 | 1.65 | 0.36 | 2.37 | 2000 | 610 |
26 | 7/0.16 | 0.49 | 0.64 | 1.77 | 0.36 | 2.49 | 2000 | 610 |
24 | 11/0.16 | 0.61 | 0.64 | 1.89 | 0.36 | 2.61 | 2000 | 610 |
22 | 17/0.16 | 0.76 | 0.64 | 2.04 | 0.36 | 2.76 | 2000 | 610 |
20 | 26/0.16 | 0.94 | 0.64 | 2.22 | 0.36 | 2.94 | 2000 | 610 |
18 | 41/0.16 | 1.18 | 0.64 | 2.46 | 0.36 | 3.18 | 2000 | 610 |
16 | 26/0.254 | 1.49 | 0.64 | 2.77 | 0.36 | 3.49 | 2000 | 610 |
14 | 41/0.254 | 1.89 | 0.64 | 3.17 | 0.36 | 3.89 | 2000 | 610 |
12 | 65/0.254 | 2.37 | 0.64 | 3.65 | 0.36 | 4.37 | 2000 | 610 |
10 | 104/0.254 | 2.99 | 0.64 | 4.27 | 0.36 | 4.99 | 2000 | 610 |