·Strand, tinned or bare conductor,30 AWG – 10 AWG
·Color-coded FEP insulation.
·Rated temperature:-80℃ ~ +150℃.
·Rated voltage: 600volts .
·Uniform thickness of wire to ensure easy stripping and cutting.
·Resistant to acids, alkalies, oils, flame retardant, fire resistance, and low smoke, non-halogen.
·Refer to standards UL 758,UL1581 and CSA C22.2 No.210.2, passes UL VW-1 & CSA FT1 vertical flame test.
·Color-coded FEP insulation.
·Rated temperature:-80℃ ~ +150℃.
·Rated voltage: 600volts .
·Uniform thickness of wire to ensure easy stripping and cutting.
·Resistant to acids, alkalies, oils, flame retardant, fire resistance, and low smoke, non-halogen.
·Refer to standards UL 758,UL1581 and CSA C22.2 No.210.2, passes UL VW-1 & CSA FT1 vertical flame test.
APPLICATIONS
·Widely applied in aviation; metallurgy and petroleum industry as well as applied in other products such as :electronic instrument & device, electrical appliance, leads for transformer electrical motor.
CONSTRUCTION:
Size | Conductor construction | Stranding Diameter | Insulation Thickness | Overall Diameter | Weight | |
AWG | No./mm | mm | mm | mm | Conductor | Insulator |
30 | 7/0.10 | 0.31 | 0.51 | 1.35 | 0.307 | 1.788 |
28 | 7/0.12 | 0.37 | 0.51 | 1.40 | 0.442 | 1.915 |
26 | 7/0.16 | 0.49 | 0.51 | 1.55 | 0.786 | 2.365 |
24 | 7/0.20 | 0.61 | 0.51 | 1.65 | 1.228 | 2.514 |
22 | 19/0.15 | 0.76 | 0.51 | 1.80 | 1.875 | 2.889 |
20 | 19/0.19 | 0.94 | 0.51 | 2.00 | 3.015 | 3.487 |
18 | 19/0.235 | 1.18 | 0.51 | 2.20 | 4.600 | 3.904 |
16 | 19/0.30 | 1.49 | 0.51 | 2.55 | 7.500 | 4.984 |
14 | 19/0.375 | 1.89 | 0.51 | 2.95 | 11.72 | 6.240 |
12 | 19/0.48 | 2.37 | 0.51 | 3.40 | 19.20 | 7.588 |
10 | 37/0.43 | 2.99 | 0.51 | 4.05 | 30.00 | 9.984 |