·Stranded, tinned or bare copper conductor, 18AWG – 14AWG .
·EPR insulation and CPE Jacket.
·Rated temperature: 105℃.
·Rated voltage: 600 volts .
·Refer to standard UL 62.
·Refer to standards UL 758, UL 1581 & CSA C22.2 No. 210.2; Passes UL VW-1 and CSA FT2 flame test.
·EPR insulation and CPE Jacket.
·Rated temperature: 105℃.
·Rated voltage: 600 volts .
·Refer to standard UL 62.
·Refer to standards UL 758, UL 1581 & CSA C22.2 No. 210.2; Passes UL VW-1 and CSA FT2 flame test.
APPLICATIONS
Suitable for extra hard-service cords of electrical appliances with supply voltage below 600V.
CONSTRUCTION:
Size | Conductor construction | No. of Core | Insulation Thickness | Nom. Diameter | Jacket Thickness | Overall Diameter | Standard put-up | |
AWG | No./mm | No. | mm | mm | mm | mm | Feet/coil | Meter/coil |
18 | 41/0.16 | 2 | 0.69 | 2.80 | 1.22 | 8.80 | 2000 | 610 |
18 | 41/0.16 | 3 | 0.69 | 2.80 | 1.22 | 9.40 | 2000 | 610 |
18 | 41/0.16 | 4 | 0.69 | 2.80 | 1.22 | 10.00 | 2000 | 610 |
16 | 65/0.16 | 2 | 0.69 | 3.10 | 1.22 | 9.40 | 2000 | 610 |
16 | 65/0.16 | 3 | 0.69 | 3.10 | 1.22 | 10.00 | 2000 | 610 |
16 | 65/0.16 | 4 | 0.69 | 3.10 | 1.22 | 10.60 | 2000 | 610 |
14 | 41/0.254 | 2 | 1.04 | 4.10 | 1.62 | 12.80 | 2000 | 610 |
14 | 41/0.254 | 3 | 1.04 | 4.10 | 1.62 | 13.50 | 2000 | 610 |
14 | 41/0.254 | 4 | 1.04 | 4.10 | 1.62 | 14.50 | 2000 | 610 |